UNI-T UT07B-EU power outlet tester
- Ships today! The product is in stock at our warehouse located in Finland. Orders are shipped at lightning speed usually the same or next business day. Delivery time depends of the destination country.
- Ships in 4–7 days The product is shipped from supplier warehouse and delivered first to our warehouse located in Finland. You will receive a tracking link by email once we have shipped your order from our warehouse, usually within 4–7 business days after your order.
- Out of stock The product is currently unavailable. Please send a message to our customer service for more information.
Please take a look of our Shipping methods and costs page for more information.
Do you have any question?
We prefer that you send your message with our live chat. Contacting us with the chat allows us to see the product & page where you at the moment so it will be faster for us to check the product you are interested.
We can help you immediately if we are available, if we are busy packing orders we will get back to you and contact you by email & live chat.
If you are in a hurry you can leave your message with the contact form.
Would you like to place a larger wholesale order? Or would like to request for quotation for custom order?
Request for quatation:
- Add all the items and quantities into the cart
- Go to the "Cart page" by clicking this link or click the "Contact us" button in the slider cart.
- In the "Cart page" you can click the "Contact us" button and you can send a message and quote request for your cart items.

Description
Product information
UNI-T UT07B-EU power outlet tester
The UNI-T UT07B-EU mains socket tester is an expanded version of the UT07A-EU model, which, in addition to standard cable diagnostics, also offers a built-in residual current device (RCD). Thanks to this, the device not only detects irregularities in the wiring of the installation, but also allows you to check the effectiveness of the electric shock protection.
Built-in RCD test - greater safety
The most important difference in the UT07B-EU model is the presence of an RCD test function. The device generates a leakage current of about 30 mA, which allows you to check whether the residual current circuit breaker is working properly. This is especially important in new installations, where the RCD is the primary element of protection against electric shock.
Quick diagnostics of installation errors
The UT07B-EU makes it possible to detect common faults, such as the absence of a neutral or protective conductor, the swapping of phase and neutral wires, as well as incorrect ground connections. Thanks to clear light indications, the user immediately knows what problem he is dealing with.
Operating voltage and frequency
The tester operates at 230 V and a frequency of 50-60 Hz, i.e. fully in accordance with European power grid standards. This makes it suitable for most installations found in homes, offices or workshops.
| Manufacturer | UNI-T |
|---|---|
| Model | UT07B-EU |
| Operating voltage | 230 V |
| Operating current | <18 mA |
| Frequency | 50 Hz ~ 60 Hz |
| RCD | ~30 mA |
| Indicator of correct connection | Yes |
| No grounding indicator | Yes |
| Indicator of no neutral wire | Yes |
| Weight | 80,5 g |
| Dimensions | 65 x 65 x 61 mm |
Warranty: 24 months
UNI-T UT07B-EU power outlet tester
The UNI-T UT07B-EU mains socket tester is an expanded version of the UT07A-EU model, which, in addition to standard cable diagnostics, also offers a built-in residual current device (RCD). Thanks to this, the device not only detects irregularities in the wiring of the installation, but also allows you to check the effectiveness of the electric shock protection.
Built-in RCD test - greater safety
The most important difference in the UT07B-EU model is the presence of an RCD test function. The device generates a leakage current of about 30 mA, which allows you to check whether the residual current circuit breaker is working properly. This is especially important in new installations, where the RCD is the primary element of protection against electric shock.
Quick diagnostics of installation errors
The UT07B-EU makes it possible to detect common faults, such as the absence of a neutral or protective conductor, the swapping of phase and neutral wires, as well as incorrect ground connections. Thanks to clear light indications, the user immediately knows what problem he is dealing with.
Operating voltage and frequency
The tester operates at 230 V and a frequency of 50-60 Hz, i.e. fully in accordance with European power grid standards. This makes it suitable for most installations found in homes, offices or workshops.
| Manufacturer | UNI-T |
|---|---|
| Model | UT07B-EU |
| Operating voltage | 230 V |
| Operating current | <18 mA |
| Frequency | 50 Hz ~ 60 Hz |
| RCD | ~30 mA |
| Indicator of correct connection | Yes |
| No grounding indicator | Yes |
| Indicator of no neutral wire | Yes |
| Weight | 80,5 g |
| Dimensions | 65 x 65 x 61 mm |
Warranty: 24 months